A quality modular
building system for temporary and semi permanent
applications
The
A1 SUPALINK modular building system has developed
to provide a high standard in specification and
interior finish making them suitable for all
levels of industrial and commercial application.
The building modules are constructed to a 3m
width module and are available in standard
lengths of 7.2m, 8.4m and 9.2m. The modules can
be linked in side to side, end to end or side to
end configurations. The standard construction can
be installed in single and two storey buildings.
Statutory
Requirements
All units manufactured in accordance with the
following;
BS CP3
Part 1 Dead Loads
BS CP3 Part 2 Wind Loads
BS CP3 Part 2 Structural Use of Timber
Floor Loading 3Kn/m2
Roof Loading 0.75Kn/m2
|
|
General Construction
Floor: Constructed from 160mm x 50mm steel perimeter
beam supporting 170mm x 50mm joists at 400mm centres. The
floor is 18mm flooring grade, moisture resistant particle
board covered in 2mm solid vinyl sheet with welded
joints.
The floor structure is insulated with TL2 insulation
system complete with 25mm air gap to provide 0.45
W/m2/Deg C heat loss.
Walls: The walls are timber stud construction
formed by 80mm x 34mm timbers set at 400mm centres and
clad externally with 9mm external WBP plywood or moisture
resistant particle board, finished, as standard, in a
resin based texture. The internal cladding is 12.5mm
emulsioned plasterboard giving a notional half hour fire
resistance. The wall structure is insulated with 80mm
fibreglass to provide 0.45 W/m2/Deg C heat
loss.
Plastic coated steel and Stenni aggregate external
treatments can be provided at extra cost. A number of
optional internal finishes can be supplied. These
include; decorative woodgrain plywoods, vinyl coated
plywoods and plasterboard, and a variety of hard wearing
melamine faced boards.
Roof: The roof construction provides a ventilated
roof space with traditional rainwater disposal. The
structure is formed by a steel lattice roof beams
supported on 100mm x 50mm full height box sections. The
roof deck is 9mm CDX plywood or moisture resistant
particle board, supported by 100mm x 34mm roof beams, and
protected with a single membrane, single piece roof
blanket providing an FAA fire rating.
The ceiling is lined with 12.5mm emulsioned plasterboard
supported on 100mm x 34mm ceiling joists and the roof
space is insulated with 100mm fibreglass providing
0.25W/m2/Deg C heat loss.
Windows: Faced fixed, single glazed aluminium
windows are fitted providing natural ventilation by means
of top opening vents. Double glazing is an option at
extra cost.
Doors: External doors are 762mm solid core flush
doors with a painted finish to the client's choice. Doors
are hung on three steel butt hinges and fitted with
2-lever mortice locks and SAA furniture.
Electrical Installation: All electrical
installations are in accordance with IEE regulations 16th
Edition. |